This ELSD has been developed as well for ultrafast HPLC.
The light source is a 405 nm laser, which increases the sensitivity even further.
Sedere’s unique Low-Temperature-Technology allows outstanding analytical results to be achieved with this detector.
As a universal detector, an ELSD offers numerous possibilities for detecting substances that have few or no chromophores. Since the eluents are evaporated, the use of non-UV-compatible solvents poses no problems and the ELSD is gradient compatible.
Complete SOP protocols for GLP conformity and validation procedures are available.
Arrange a date with us for a demonstration and experience the efficiency of this detector
Further models:
Sedex 85 "the standard" and Sedex 80 "the cost-effective option"
With the aid of the nebulizer, the mobile phase is transformed into a fine droplet mist. The Sedex LT technology ensures that only the finest droplets enter the evaporation unit. Larger droplets increase the baseline noise considerably.
This discrimination of the larger droplets allows a very low evaporation temperature so that with reduced baseline noise it is possible to detect even semi-volatile substances.
The mist and the molecules dissolved in it are transported with the aid of GSF (gas supported focusing) to an optical unit for measurement of light-scattering. This bundling of the dissolved particles with the aid of the inert gas allows highly sensitive detection. It also prevents contamination of the optical unit by samples particles.
HPLC: from 4 µl/min to 4 ml/min mit 4 different nebulizers
SFC: 1 nebulizer
Special nebulizer clips for micro HPLC, as well as thermostatically controlled
glass cells on request.
See Sedere accessories for a list of nebulizers and spare parts
Sedere accessories
For example, for the detection of:
* carbohydrates
* proteins
* peptides
* polymers
* lipids
* steroids
Detection: | highly sensitive photomultiplier |
Sensitivity: | LOD: 0,5 ng stearic acid on column |
Light source: | 10 mW - 405 nm Laser, operating hours counter |
Nebulizer: | Optimisation by selectable nebulizers |
Flow rate: | 100 µl/min – 5 ml/min |
Temp. range: | ambient temperature to 85°C |
Gas feed line: | automatic shut-off on the display and via software control |
Output signal: | analogue 0-1V |
Datenrate: | analogue 100 Hz |
System control: | Software control for temperature, measuring range and gas shut-off; connection for external events by short circuit- or TTL-signal |
Software: | drivers available for ChemStation™, EZChrom, Xcalibur™ and Clarity™ |
GLP conformity: | audit trail, Passwort, Adminmode |
Communication: | USB, serial RS232 interface |
Gas consumption | less than 3 l/min; at 3.5 bar normal operation |
Dimensions: | 250 x 480 x 550 mm (w x d x h) |
Weight: | 18,5 kg |
Please request our applications example, we will be happy to send it to you:
ELSD Applications
New Applications for the Sedex 90 LT:
Analysis_of_Amino_Acids
Analysis_of_Organic_Acids
Method_for_Carbohydrates
Method_for_Inorganic_Icons
Method_for_Lipids
Method_for_Lipids_02
Method_for_Vitamins
Tel.: +49 89 660 55 696
E-mail: partner@erc-hplc.de
Nebulizers and spare parts can be found at:
Sedex accessories