Thermostatic Column Selection System

MistraSwitch Column Selection System



The most efficient way ... MistraSwitch!











Fully automated temperature controlled column selection within a chromatography data system is the ideal way for unattended and overnight operation when using different methods with different columns and temperature.

The MistraSwitch system solution of the company MayLab is designed for fully automated selection for up to 10 UHPLC columns (up to 15000 psi) or 10 HPLC columns (up to 5000 psi) under temperature control using a Mistral column thermostat. The System consists of a Mistral column thermostat, 2 motordriven valves (VICI Cheminert) and the MS 5000 interface, built into a rugged housings.

Software drivers are available for all well-known chromatography data systems.

Performance Characteristics

Performance Characteristics

  • separate electrical heating and peltier cooling 

  • Temparature range from 5°C to 75°C

  • passive capillary pre-heater

  • Leakage Sensor with pump shut down output

  • unrivalled temperature stability and -precision: < 0,1°C   
     
  • fast heating speed, 10°C/min and cooling speed, 3°C/min

  • Column compartment space for up to 10 HPLC columns (300 x 4,6 mm)

  • Valve switching speed <100 ms

  • patented microprocessor controlled valve actuating

  • Interface: RS 232 or USB 

  • very rugged, reliable and laboratory proven construction 

  • ready-to-use system

Software drivers

Software drivers

are available for:

→   Agilent ChemStation 16 bit and 32 bit 
   Dionex Chromeleon V 6.4 and higher
   AB Sciex Analyst V 1.4.1 and higher
   Thermo Scientific ChomQuest V 4.1 and higher
   Thermo Scientific Xcalibur V 1.4 and higher
   Agilent EZChrom Elite V 3.1.4 and higher

MistraSwitch and GLP

MistraSwitch and GLP

Both valve drives are selecting the column at exactly the same time.
The actual column position is constantly being reported over the interface to the driver software, as well as the actual oven temperature. 

Error reports are displayed (eg faulty valve) and if necessary, th actual running method is stopped immediately. 

Each switching cycle is recorded in a log file, including action, time and date stamp. Thereby the systems activities will be manageable and reproducible for the operator.

Models

Models

Order Code

Product

HPLC System, consisting of 2 motor-driven Column Selector Valves 5000 psi, with Mistral 886

ML-MSF04VC

4 HPLC Column Selection System (0,4 mm bore)

ML-MSF06VC

6 HPLC Column Selection System (0,4 mm bore)

ML-MSF08VC

8 HPLC Column Selection System (0,4 mm bore)

ML-MSF10VC

10 HPLC Column Selection System (0,4 mm bore)

ML-MSF04VCA

4 HPLC Column Selection System (0,25 mm bore)

ML-MSF06VCA

6 HPLC Column Selection System (0,25 mm bore)

ML-MSF08VCA

8 HPLC Column Selection System (0,25 mm bore)

ML-MSF10VCA

10 HPLC Column Selection System (0,25 mm bore)

UHPLC System, consisting of 2 motor-driven Column Selector Valves 15000 psi, with Mistral 886

ML-MSF06VC15K

6 UHPLC Column Selection System (0,25 mm bore)

ML-MSF10VC15K

10 UHPLC Column Selection System (0,25 mm bore)

UHPLC System, consisting of 2 motor-driven Column Selector Valves 15000 psi, with Mistral 886
15000 psi valve at input, 5000 psi valve at output

ML-MSF06VC15K5K

6 UHPLC Column Selection System (0,25 mm bore)

ML-MSF10VC15K5K

10 UHPLC Column Selection System (0,25 mm bore)

Software Drivers

ML-MSFS1

for AB Sciex Analyst V 1.4.1 and higher

ML-MSFS2

for Agilent ChemStation 16 bit and 32 bit

ML-MSFS3

for Dionex Chromeleon V 6.4 and higher

ML-MSFS4

for Thermo Scientific ChromQuest  V 4.1 and higher

ML-MSFS5

for Thermo Scientific Xcalibur V 1.4 and higher

ML-MSFS6

for Agilent EZChrom Elite V 3.1.4 and higher

Included in Delivery:
- 2x MS 5000 valve drives with 4, 6, 8 or 10 port VICI Cheminert valves
- MS 5000 Interface (Column selection controller)
- Mistral serier 886 column thermostat
- suitable PEEK or Stainless Steel Fittings for VICI valves 
- all required cables for connecting    
- Instruction Manual