ELSD Light Scattering Detectors - Sedex LC

Evaporative Light Scattering Detector Sedex LC


 
 
  The preparative ELSD

  With innovative SAGA technology.

  Worldwide the first ELSD with a dynamic range 
  of at least 4 powers of ten!

  Ideal for preparative applications.







The ELSD Sedex LC allows the analysis of all non-volatile compounds. For the detection chromophores, electroactive
or fluorescent groups are not required. The Low-Temperature Technology allows the measurement at very low evaporative temperatures, which even affords the detection of semi-volatile compounds. Extremely low sample loss through flow rates down to 200 µl/min by using a suitable Flow Splitter.

This ELSD combines high sensitivity, reliability and accuracy. It can be connected to any HPLC system.
One can control the detector manually or via PC, using the most common software drivers.

Complete SOP protocols for GLP conformity and validation procedures are available.

Arrange a date with us for a demonstration and experience the efficiency of this ELSD Sedex LC

Performance characteristics

  • SAGA, the automated gain adjustment! 
    When the detector is driver-controlled by software, the Sedex LC automatically adapts the gain setting to avoid any off-scale saturation of the detector

  • The dedicated Sedex LC Nebulizer is qualified for flowrates from 
    200 μl/min to 2 ml/min and can be easily mounted and dismounted

  • Complete Remote Control: the gas, heater, photodiode
    and light source can be automatically shut off at the end
    of a series of analyse

  • Optimization of detection possibilities of non-volatile, thermally labile and semi-volatile compounds

  • Unrivalled cost-performance ratio

Further models: 
ELSD Sedex 85    best cost/performance ratio 
ELSD Sedex 90    the standard
ELSD Sedex 100  the most sensitive with SAGA

Function principle

  • Splitting

With the aid of the nebulizer, the mobile phase is transformed into a fine droplet mist. The Sedex LT technology ensures that only the finest droplets enter the evaporation unit. Larger droplets increase the baseline noise considerably.

  • Low evaporation temperature

This discrimination of the larger droplets allows a very low evaporation temperature so that with reduced baseline noise it is possible to detect even semi-volatile substances.

  • GSF™  bundling via inert gas

The mist and the molecules dissolved in it are transported with the aid of GSF (gas supported focusing) to an optical unit for measurement of light-scattering. This bundling of the dissolved particles with the aid of the inert gas allows highly sensitive detection. It also prevents contamination of the optical unit by samples particles.

Chromatogram

Demonstration of the high dynamic range


Demonstration of the high dynamic range

Sample:

5 - 50.000 ppm Sulfanilamid

Injection volume:

20 µl

Eluent:

1 ml/min Water/ACN 70/30

Column:

Zorbax Eclipse XDB-C18

Detector settings:

Gain: Dynamic
Temperature: 50° C
Filter: 2 sec

Range of uses

For example, for the detection of:

    *  Carbohydrates and similar compounds
    *  Detergents, ionic and non-ionics
    *  Artificial sweeteners
    *  Antioxidants
    *  Amino acids
    *  Lipids
    *  Peptides
    *  Polymeres
    *  Pestizides
    *  Proteines
    *  Steroides

Drivers

Vendor

Software

SEDEX 85

SEDEX 90

SEDEX 100

SEDEX FP

SEDEX LC

Agilent



ChemStation Edition™

OpenLab ChemStation
Edition™

EZChrom Elite™

OpenLab EZChrom
Edition™

DataApex

Clarity™



Knauer

PurityChrom™5

ChromGate™



Thermo Fisher (Dionex)



Chromeleon™6.8

Chromeleon™7.2

ChromQuest™

Xcalibur™



SCPA

PrepCon™5

Chromstar™7



Specifications

Detection: 

Photodiode with SAGA

Sensitivity:

5 ng 

Light Source:

Blue LED, Elapsed Time Counter

Nebulizer: 

LC

Flow Rate: 

200 µl/min - 2 ml/min

Temperature Range: 

Ambient to 100°C

Gain Settings:

1 to 7

Filter: 

dedicated Numerical Algorithm

Output Signal: 

analog 0-1 Volt

Data Rate:

40 Hz

Events:

Contact Closure, TTL, Autozero

Powerdown Methods: 

Gas, Light Source, Heating and/or Photodiode; 
Cleaning Mode

Interface:

USB, RS-232

Gas Supply: 

Nitrogen or or Highly Clean Pressured Air, min. 3,5 bar (less than 3 l/min)

Dimensions:

250 x 330 x 530 mm (B x H x T)

Weight:

15 kg

Öffnet einen internen Link im aktuellen FensterSpecifications of all Sedex ELSD's

Legal

Managing Director:
Joachim Paschlau

HRB 135721 München
WEEE-Reg.Nr. DE 66898529

ERC GmbH

Gesellschaft für den Vertrieb wissenschaftlicher Geräte
Otto-Hahn-Strasse 28-30
85521 Riemerling
GERMANY
Tel: +49 89 66055696
Fax: +49 89 60824826
partner@erc-hplc.de