ELSD Light Scattering Detector
Sedex FP

Evaporative Light Scattering Detector Sedex FP



  For Flash Chromatography

  Special SEDEX FP Nebulizer.

  With SAGA technology.






Flash chromatography is a cost-effective and convenient fast chemical separation process used in laboratories for the purification and isolation of active ingredients. It is an established method in chemical synthesis, pharmacokinetics or combinatorial chemistry.

By using a Sedex FP, a time- and cost-intensive preparative HPLC separation is unnecessary. This ELSD is easy to use, requires little space and can detect and monitor your fractions collection in two simple steps.

With the innovative SAGA technology (Sedex Automated Gain Adjustement), you can select a dynamic gain setting to avoid an offset saturation of the detector. Detection requires neither chromophores nor electro-active or fluorescent groups.

The detector is equipped with an external splitter. Complete SOP protocols for GLP compliance and validation requirements are available.

Performance characteristics

Performance characteristics

  • Special Sedex FP nebulizer, suitable for flow rates from 100 μL/min to 5mL/min, can be easily installed and removed

  • Gas-focusing technology in the optical detection cell prevent clogging and contamination

  • SAGA, the automated gain adjustment

  • Evaporation of the mobile phase at low temperatures
    (Low-Temperature Technology)

  • Optimization of detection possibilities of semi-volatile and thermally labile compounds

  • Complete Remote Control: the gas, heater, photodiode
    and light source can be automatically shut off at the end
    of a series of analyse

Further models: 
ELSD Sedex 85:   the low priced
ELSD Sedex 90:    the standard
ELSD Sedex 100:  the most sensitive with SAGA
ELSD Sedex LC:    the preparative

Function principle

Function principle

  • Splitting

With the aid of the nebulizer, the mobile phase is transformed into a fine droplet mist. The Sedex LT technology ensures that only the finest droplets enter the evaporation unit. Larger droplets increase the baseline noise considerably.

  • Low evaporation temperature

This discrimination of the larger droplets allows a very low evaporation temperature so that with reduced baseline noise it is possible to detect even semi-volatile substances.

  • GSF™  bundling via inert gas

The mist and the molecules dissolved in it are transported with the aid of GSF (gas supported focusing) to an optical unit for measurement of light-scattering. This bundling of the dissolved particles with the aid of the inert gas allows highly sensitive detection. It also prevents contamination of the optical unit by samples particles.

Chromatogram

Chromatogram

Chromatogram ELSD Sedex FP

Injection volume:

2 µl

Eluent:

A - 0.1% TFA in H2O; B - 0.1 % TFA in Acetonitrile

Gradient:

0-0.5 min: 2%B to 60%B, 15-20 min: 60%B

Flowrate: 

0,3 mL/min

Column:

Ascentis Express Peptide ES-C18 (2.7 µm, 2.1x150 mm), 250 C

Range of uses

Range of uses

For example, for the detection of:

    *  Carbohydrates and similar compounds
    *  Detergents, ionic and non-ionics
    *  Artificial sweeteners
    *  Antioxidants
    *  Amino acids
    *  Lipids
    *  Peptides
    *  Polymeres
    *  Pestizides
    *  Proteines
    *  Steroides

Drivers

Drivers

Vendor

Software

SEDEX 85

SEDEX 90

SEDEX 100

SEDEX FP

SEDEX LC

Agilent



ChemStation Edition™

OpenLab ChemStation
Edition™

EZChrom Elite™

OpenLab EZChrom
Edition™

DataApex

Clarity™



Knauer

PurityChrom™5

ChromGate™



Thermo Fisher (Dionex)



Chromeleon™6.8

Chromeleon™7.2

ChromQuest™

Xcalibur™



SCPA

PrepCon™5

Chromstar™7



Spezifications

Spezifications

Detection: 

Photodiode

Sensitivity:

100 ng 

Light source:

Blue LED, Elapsed Time Counter

Nebulizer: 

Flash

Flow Rate: 

100 µl/min - 5 ml/min

Temperature Range: 

Ambient to 100°C

Gain Settings:

1 to 8

Filter:

0 to 10s

Data Rate:

10 Hz

Events: 

Contact Closure, TTL, Autozero

Powerdown Methods:

Gas, Light Source, Heating and/or PMT; Cleaning Mode

Computer Interface:

RS-232 

Gas Supply: 

Nitrogen or or Highly Clean Pressured Air 2,0 bar (less than 3 l/min)

Dimensions
(W x H x D):

250 x 330 x 530 mm 

Weight:

15 kg