ELSD Light Scattering Detector
Sedex 100

Evaporative Light Scattering Detector Sedex 100

  The most sensitive ELSD on the market 
  with SAGA! 

  Up into the lower-pg range. 

  Patented SAGA technology. 

  Blue high perfomance laser.

  For HPLC, UHPLC and SFC.






The innovative SAGA technology (Sedex Automated Gain Adjustment) of the new ELSD Sedex 100, when controlled via a driver, automatically adjusts the sensitivity of the detector during the analysis. This prevents peaks being cut off and the dynamic range of the detector is increased by a factor of 5 to the power of 10. Detection requires neither chromophores nor electro-active or fluorescent groups.

In this new ELSD generation put 25 years of experience and development work. 
The new optical unit based on a new high-power laser, thus the best signal-/noise ratio. New design to minimise peak width and the digital signal processing using innovative algorithms also contribute to the outstanding sensitivity of the ELSD Sedex 100.

The Sedex 100 can be integrated into any HPLC or SFC system. Control is either manual via the detector itself or using most commonly available software drivers. Various nebulisers for flow rates of just a few µl/min to several ml/min can be obtained for optimisation of the application (also for SFC). Comprehensive SOP protocols for GLP conformity as well as validation procedures are available. 

Performance characteristics

Performance characteristics

  • SAGA, the automated gain adjustment! 
    When the detector is driver-controlled by software, the Sedex 100 automatically adapts the gain setting to avoid any off-scale saturation of the detector

  • Blue high-power laser

  • New design to minimise peak width

  • High dynamic range (over 5 power of ten)

  • Complete Remote Control: the gas, heater, photodiode
    and light source can be automatically shut off at the end
    of a series of analyse

  • Optimization of detection possibilities of non-volatile and thermally labile compounds

Further models:
ELSD Sedex 85    the low priced
ELSD Sedex 90    the standard
ELSD Sedex LC    the preparative

Function principle

Function principle

  • Splitting

With the aid of the nebulizer, the mobile phase is transformed into a fine droplet mist. The Sedex LT technology ensures that only the finest droplets enter the evaporation unit. Larger droplets increase the baseline noise considerably.

  • Low evaporation temperature

This discrimination of the larger droplets allows a very low evaporation temperature so that with reduced baseline noise it is possible to detect even semi-volatile substances.

  • GSF™  bundling via inert gas

The mist and the molecules dissolved in it are transported with the aid of GSF (gas supported focusing) to an optical unit for measurement of light-scattering. This bundling of the dissolved particles with the aid of the inert gas allows highly sensitive detection. It also prevents contamination of the optical unit by samples particles.

Chromatogram

Chromatogram


Sample:


➊Coffein (50.000 ng on column)
➋Hydrocortison (25 ng on column)

Injections olume:

10 µl

Eluent:

Water/ACN 70/30

Flowrate:

1 ml/min

Column:

Zorbax Eclipse XDB-C18; 3,0x100 mm; 3,5 micron

Detector Settings:

Gain: Dynamic
Temperature: 75° C
Filter: 2 sec


Dynamic Range

Dynamic Range


Sample: 


Sulfanilamid

Injection:

10 µl

Eluent:

Wasser/ACN 70/30

Flowrate:

1 ml/min

Column: 

Zorbax Eclipse XDB-C18, 3,0x100mm, 3,5-micron

Detector Settings:

Gain: Dynamic; Temperature: 60o C; Filter: 2 sec


Range of uses

Range of uses

For example, for the detection of:

    *  Carbohydrates and similar compounds
    *  Detergents, ionic and non-ionics
    *  Artificial sweeteners
    *  Antioxidants
    *  Amino acids
    *  Lipids
    *  Peptides
    *  Polymeres
    *  Pestizides
    *  Proteines
    *  Steroides

Drivers

Drivers

Vendor

Software

SEDEX 85

SEDEX 90

SEDEX 100

SEDEX FP

SEDEX LC

Agilent



ChemStation Edition™

OpenLab ChemStation
Edition™

EZChrom Elite™

OpenLab EZChrom
Edition™

DataApex

Clarity™



Knauer

PurityChrom™5

ChromGate™



Thermo Fisher (Dionex)



Chromeleon™6.8

Chromeleon™7.2

ChromQuest™

Xcalibur™



SCPA

PrepCon™5

Chromstar™7



Specifications

Specifications

Detection: 

Photodiode with SAGA

Sensitivity:

< 250pg 

Light Source:

Blue High-Power Laser, Elapsed Time Counter

Nebulizer: 

Low Flow, HPLC, SFC, UHPLC

Flow Rate: 

500 µl/min - 2 ml/min

Temperature Range: 

Ambient to 100°C

Gain Settings:

1 to 7 or SAGA (patented, dynamic Auto-Gain)

Filter: 

Dedicated Numerical Algorithm

Output Signal: 

Analog 0-1 Volt

Data Rate:

up to 100 Hz

Events:

Contact Closure, TTL, Autozero

Powerdown Methods: 

Gas, Light Source, Heating and/or Photodiode; 
Cleaning Mode

Interface:

USB, RS-232

Gas Supply: 

Nitrogen or Highly Clean Pressured Air, min. 3,5 bar (less than 3 l/min)

Dimensions:

250 x 330 x 530 mm (W x H x D)

Weight:

15 kg