Ihr direkter Kontakt zu uns:
www.erc-hplc.de » LC Detectors » Electrochemical Detectors » Electrochemical Detectors DECADE »

Electrochemical Detectors DECADE Elite

ECD DECADE Elite



  Also suitable for super-fast UHPLC!


  With its measurement frequency up to 100 Hz, 
  this electrochemical Detector is specially designed
  for super-fast, highly sensitive and selective 
  measurement of oxidisable and reducible
  substances in (U)HPLC.









DECADE Elite comprises a thermostat-controlled Faraday’s cage, accommodating column and flow cell.
It unites the three operating modes DC, Pulse and Scan in one instrument. Almost all applications are covered by the DC mode. The pulse mode is important for PAD (Pulsed Amperometric Detection) of e.g. Carbohydrates. To obtain a voltammogram in the method optimization, the scan mode is used. A digital low-pass filter provides an excellent signal-to-noise ratio.

For highest sensitivity, the SenCell flow cell with glassy carbon electrode is recommended with a 5 year warranty. 

Arrange a date with us for a demonstration and experience the efficiency of these Electrochemical Detectors

Performance characteristics

  • highest sensitivity – down to the low fentomol range (on column)
  • excellent precision due to thermostatically controlled Faraday’s cage for measuring cell and column

  • flexible and efficient due to control of up to 4 cells

  • wide selection of working and reference electrodes

  • optimised signal to noise ratio via ADF (advanced digital filter)

  • can be updated using flash-technology

  • well-arranged display, screw connection for sample feed at the front

Flow Cells and Electrodes

The following flow cells are available:


SenCell
 
- the new generation - for highest sensitivity!

                

The SenCell is a wall-jet cell and designed for maximum sensitivity.
The cell is small, robust and easy to handle. Instead of a polymer spacer, the distance to the working electrode is continuously adjustable, without opening
 the cell. This allows you to quickly customize a method for optimal detection performance.
Öffnet einen internen Link im aktuellen FensterSenCell


The VT-03 Cell was developed for highest sensitivity. Owing to its variable volume from 0.3 µl to 5 nl it can be used for both standard flow rates and µ-bore or capillary LC. Working electrodes made from glassy carbon, platinum, gold, silver or copper are available.


 With the FlexCell, working and reference electrodes can be quickly exchanged. All parts of the cell can be exchanged separately at low cost. The FlexCell is particularly suitable for applications involving working electrodes made of metal and as a reactor preceding another measuring cell. Working electrodes: made from glassy carbon, platinum, gold, silver or diamond.


 Choose from the following reference electrodes:

Standard:

ISAAC (in-situ Ag/AgCl)

Classical:

Ag/AgCl

Extreme conditions:

Hy-REF maintenance free, pH 1-14, organic eluents

 
An overview of all electrochemical cells and spare parts with order no
you will find here:
Öffnet einen internen Link im aktuellen FensterDECADE - Flow Cells and Spare parts

Range of uses

Clinical diagnostics:

biogenic amines and metabolites, homocysteine, iodide, vitamins

Neuroscience:

Neurotransmitters, markers for oxidative stress

Food:

Carbohydrates, polyphenols, antioxidants, iodide

Pharmaceutical:

Antibiotics, fluorodeoxyglucose

Environment:

Phenols and polyphenols, bisphenol A, pesticides

Specifications

Operation modes:

DC, Puls, Scan

Potential ranges:

-2,0 V to +2,0 V

Potential range MD:

-2,5 V to +2,5 V, activation of the diamond electrode

Signal outlet:

-1,0 V to +1 V or -10 V to +10 V (20 bit D/A converter)

Offset:

-50% to +50% of the measuring range

Autozero:

triggered via key, TTL, RS-232

RS-232:

detector control, data transmission with 1, 2, 5 or 10 Hz

Oven:

from 7°C above ambient temperature to 45°C

Dimensions(wxdxh):

22 x 44 x 44 cm

Weight:

14,6 kg without column and flow cell

DC MODE

Measuring range:

         10 pA-200 μA in steps off 1,2,5

Filter (cut off):

         Advanced Digital Filter, 0.5 -0.001 Hz in 1,2,5 steps

Noise:

         < 2 pA with a dummy cell

PULS MODE

Measuring range:

      10 nA–200 μA in steps of 1,2,5

Filter (cut off):

      Advanced Digital Filter, 0.5-0.001 Hz in 1,2,5 steps

Pulse times:

      t1: 100-2000 ms; t2: 0-2000 ms; t3: 0-2000 ms in 
      Schritten von 10 ms

Data recording:

      20, 40, 60, 80 and 100 ms

SCAN MODE

Measuring range:

10 nA-200 μA in steps of 1,2,5

Scan speed:

1-50 mV/s  in steps of 1,2,5

Scan cycle:

half, complete, continuous

Applications

The DECADE is a single detector as well as a part of the Alexys systems. The DECADE Elite has replaced the DECADE II. Numerous DECADE/Alexys applications are available:

Clinical and Diagnostics

Öffnet einen internen Link im aktuellen Fenster212_004_03 - Iodide in Milk
Öffnet einen internen Link im aktuellen Fenster214_001_05 - Catecholamines in Urine
Öffnet einen internen Link im aktuellen Fenster214_002_05 - Catecholamines in Plasma
Öffnet einen internen Link im aktuellen Fenster214_003_05 - Serotonin in Urine
Öffnet einen internen Link im aktuellen Fenster214_004_05 - Serotonin in Plasma
Öffnet einen internen Link im aktuellen Fenster214_005_05 - Metanephrines in Urine
Öffnet einen internen Link im aktuellen Fenster214_006_05 - HVA, VMA and 5-HIAA in Urine
Öffnet einen internen Link im aktuellen Fenster214_007_03 - Compilation of Clinical Applications
Öffnet einen internen Link im aktuellen Fenster214_008_00 - Iodide in Urine

fileadmin/content/Produkte/uploads/Antec/Applicationen_Alexys_Decade/214_008_00_-_Iodide_in_Urine_ERC.pdf
Food, Beverage and Environmental

Öffnet einen internen Link im aktuellen Fenster212_004_03 - Iodide in Milk
Öffnet einen internen Link im aktuellen Fenster216_003_03 - Phenols in Water
Öffnet einen internen Link im aktuellen Fenster216_005_07 - Bisphenol A in Water
Öffnet einen internen Link im aktuellen Fenster216_006_06 - Polyphenols in Wine and Food
Öffnet einen internen Link im aktuellen Fenster220_002_06 - Carbohydrates in Food
Öffnet einen internen Link im aktuellen Fenster220_003_03 - Mono- and Disaccharides
Öffnet einen internen Link im aktuellen Fenster220_004_01 - Mono-, Di-, Trisaccharides in Plants
Öffnet einen internen Link im aktuellen Fenster220_006_01 - Carbohydrate Analysis in Instant Coffee

Neuroscience


Öffnet einen internen Link im aktuellen Fenster211_004_04 - Glutathione and Other Disulfides
Öffnet einen internen Link im aktuellen Fenster211_005_02 - Aminothiols and Disulfides
Öffnet einen internen Link im aktuellen Fenster213_020_09 - GABA and Glutamate Histamine, Amino Acids
Öffnet einen internen Link im aktuellen Fenster213_023_13 - Acetylcholine and Choline
Öffnet einen internen Link im aktuellen Fenster213_026_01 - Compilation of Neuroscience Applications
Öffnet einen internen Link im aktuellen Fenster213_028_08 - Monoamines and Metabolites
Öffnet einen internen Link im aktuellen Fenster213_029_02 - OMD of Neurotransmitters

Pharmaceutical and Biotech

Öffnet einen internen Link im aktuellen Fenster211_004_06 - Glutathione and Other Disulfides
Öffnet einen internen Link im aktuellen Fenster211_005_02 - Aminothiols and Disulfides
Öffnet einen internen Link im aktuellen Fenster217_010_13 - Neomycin and Framycetin Sulfate in bulk drugs
Öffnet einen internen Link im aktuellen Fenster217_013_12 - Gentamicin in Sulphate in Pharmaceutals
Öffnet einen internen Link im aktuellen Fenster217_014_09 - Tobramycin in Pharmaceuticals
Öffnet einen internen Link im aktuellen Fenster217_015_12 - Amikacin and Kanamycin in Bulk Drugs
Öffnet einen internen Link im aktuellen Fenster217_017_11 - Azithromycin, Erythromycin and other Macrolide Antibiotics
Öffnet einen internen Link im aktuellen Fenster217_018_08 - Spectinomycin in Pharmaceuticals
Öffnet einen internen Link im aktuellen Fenster217_019_06 - Spectinomycin and Lincomycin
Öffnet einen internen Link im aktuellen Fenster217_025_03 - Compilation of Pharmaceutical Application
Öffnet einen internen Link im aktuellen Fenster217_026_03 - Risperidone
Öffnet einen internen Link im aktuellen Fenster217_027_03 - Clozapine
Öffnet einen internen Link im aktuellen Fenster217_028_04 - Olanzapine
Öffnet einen internen Link im aktuellen Fenster217_030_06 - Gentamicin acording EP and USP
Öffnet einen internen Link im aktuellen Fenster217_031_05 - Netilmicin Sulfate according EP
Öffnet einen internen Link im aktuellen Fenster217_032_05 - Tobramycin according EP
Öffnet einen internen Link im aktuellen Fenster217_033_04 - Heparin according USP
Öffnet einen internen Link im aktuellen Fenster217_035_03 - Epinephrine Injections according USP
Öffnet einen internen Link im aktuellen Fenster217_036_03 - Streptomycin USP method
Öffnet einen internen Link im aktuellen Fenster217_037_03 - Betadex Sulfobutyl Ether Sodium
Öffnet einen internen Link im aktuellen Fenster217_038_06 - FDG Fluorodeoxyglucose
Öffnet einen internen Link im aktuellen Fenster217_039_02 - Ethylene Glycol in Hydroxyethyl Starch

Legal

Managing Director:
Joachim Paschlau

HRB 135721 München
WEEE-Reg.Nr. DE 66898529

ERC GmbH

Gesellschaft für den Vertrieb wissenschaftlicher Geräte
Otto-Hahn-Strasse 28-30
85521 Riemerling
GERMANY
Tel: +49 89 66055696
Fax: +49 89 60824826
partner@erc-hplc.de