ERC GmbH Header
www.erc-hplc.de » LC Detectors » Electrochemical Detector » Electrochemical Detector DECADE »

ECD
DECADE Elite

the specialist




see also:
our electrochemical systems
ROXY and ALEXYS


We will be happy to advise you!
Tel. + 49 89 66055696

Back

Electrochemical Detector DECADE Elite

Electrochemical detector DECADE Elite



  Also suitable for super-fast UHPLC!


  With its measurement frequency up to 100 Hz, 
  this ECD-Detector is specially designed for 
  super-fast highly sensitive and selective 
  measurement of oxidisable and reducible 
  substances in (U)HPLC.








DECADE Elite comprises a thermostat-controlled Faraday’s cage, accommodating column and flow cell. It unites the three operating modes DC, Pulse and Scan in one instrument. A digital low-pass filter provides an excellent signal-to-noise ratio.

For highest sensitivity, the SenCell is recommended with glassy carbon electrode
with a 5 year warranty. 

Arrange a date with us for a demonstration and experience the efficiency of this electrochemical detector

Performance characteristics

Performance characteristics

  • highest sensitivity – down to the low fentomol range (on column)
  • excellent precision due to thermostatically controlled Faraday’s cage for measuring cell and column

  • flexible and efficient due to control of up to 4 cells

  • wide selection of working and reference electrodes

  • optimised signal to noise ratio via ADF (advanced digital filter)

  • can be updated using flash-technology

  • well-arranged display, screw connection for sample feed at the front

Flow Cells and Electrodes

Flow Cells and Electrodes

The following flow cells are available:


SenCell
 
- the new generation - for highest sensitivity!

                

The SenCell is a wall-jet cell and designed for maximum sensitivity.
The cell is small, robust and easy to handle. Instead of a polymer spacer, the distance to the working electrode is continuously adjustable, without opening
 the cell. This allows you to quickly customize a method for optimal detection performance.
Öffnet einen internen Link im aktuellen FensterSenCell


The VT-03 Cell was developed for highest sensitivity. Owing to its variable volume from 0.3 µl to 5 nl it can be used for both standard flow rates and µ-bore or capillary LC. Working electrodes made from glassy carbon, platinum, gold, silver or copper are available.


 With the FlexCell, working and reference electrodes can be quickly exchanged. All parts of the cell can be exchanged separately at low cost. The FlexCell is particularly suitable for applications involving working electrodes made of metal and as a reactor preceding another measuring cell. Working electrodes: made from glassy carbon, platinum, gold, silver or diamond.


 Choose from the following reference electrodes:

Standard:

ISAAC (in-situ Ag/AgCl)

Classical:

Ag/AgCl

Extreme conditions:

Hy-REF maintenance free, pH 1-14, organic eluents

 
An overview of all electrochemical cells and spare parts with order no
you will find here:
Öffnet einen internen Link im aktuellen FensterDECADE - Flow Cells and Spare parts

Range of uses

Range of uses

Clinical diagnostics:

biogenic amines and metabolites, homocysteine, iodide, vitamins

Neuroscience:

Neurotransmitters, markers for oxidative stress

Food:

Carbohydrates, polyphenols, antioxidants, iodide

Pharmaceutical:

Antibiotics, fluorodeoxyglucose

Environment:

Phenols and polyphenols, bisphenol A, pesticides

Specifications

Specifications

Operation modes:

DC, Puls, Scan

Potential ranges:

-2,0 V to +2,0 V

Potential range MD:

-2,5 V to +2,5 V, activation of the diamond electrode

Signal outlet:

-1,0 V to +1 V or -10 V to +10 V (20 bit D/A converter)

Offset:

-50% to +50% of the measuring range

Autozero:

triggered via key, TTL, RS-232

RS-232:

detector control, data transmission with 1, 2, 5 or 10 Hz

Oven:

from 7°C above ambient temperature to 45°C

Dimensions(wxdxh):

22 x 44 x 44 cm

Weight:

14,6 kg without column and flow cell

DC MODE

Measuring range:

         10 pA-200 μA in steps off 1,2,5

Filter (cut off):

         Advanced Digital Filter, 0.5 -0.001 Hz in 1,2,5 steps

Noise:

         < 2 pA with a dummy cell

PULS MODE

Measuring range:

      10 nA–200 μA in steps of 1,2,5

Filter (cut off):

      Advanced Digital Filter, 0.5-0.001 Hz in 1,2,5 steps

Pulse times:

      t1: 100-2000 ms; t2: 0-2000 ms; t3: 0-2000 ms in 
      Schritten von 10 ms

Data recording:

      20, 40, 60, 80 and 100 ms

SCAN MODE

Measuring range:

10 nA-200 μA in steps of 1,2,5

Scan speed:

1-50 mV/s  in steps of 1,2,5

Scan cycle:

half, complete, continuous

Applications

Applications

The DECADE is a single detector as well as a part of the Alexys systems. The DECADE Elite has replaced the DECADE II. Numerous DECADE/Alexys applications are available:

Clinical and Diagnostics

Öffnet einen internen Link im aktuellen Fenster214_001_04 - Catecholamines in Urine
Öffnet einen internen Link im aktuellen Fenster214_002_04 - Catecholamines in Plasma
Öffnet einen internen Link im aktuellen Fenster214_003_04 - Serotonin in Urine
Öffnet einen internen Link im aktuellen Fenster214_004_04 - Serotonin in Plasma
Öffnet einen internen Link im aktuellen Fenster214_005_04 - Metanephrines in Urine
Öffnet einen internen Link im aktuellen Fenster214_006_04 - HVA, VMA and 5-HIAA in Urine
Öffnet einen internen Link im aktuellen Fenster214_007_03 - Compilation of Clinical Applications
Öffnet einen internen Link im aktuellen Fenster214_008_00 - Iodide in Urine

Food, Beverage and Environmental

Öffnet einen internen Link im aktuellen Fenster212_004_03 - Iodide in Milk
Öffnet einen internen Link im aktuellen Fenster216_003_01 - Phenols in Water
Öffnet einen internen Link im aktuellen Fenster216_005_05 - Bisphenol A in Water
Öffnet einen internen Link im aktuellen Fenster216_006_04 - Polyphenols in Wine and Food
Öffnet einen internen Link im aktuellen Fenster220_002_05 - Carbohydrates in Food
Öffnet einen internen Link im aktuellen Fenster220_003_01 - Monosaccharides, 4-Puls-Method

Neuroscience

Öffnet einen internen Link im aktuellen Fenster211_004_04 - Glutathione and Other Disulfides
Öffnet einen internen Link im aktuellen Fenster211_005_01 - Aminothiols and disulfides
Öffnet einen internen Link im aktuellen Fenster213_020_07 - GABA and Glutamate Histamine, Amino Acids
Öffnet einen internen Link im aktuellen Fenster213_023_09 - Acetylcholine and Choline
Öffnet einen internen Link im aktuellen Fenster213_025_01 - OMD of neurotransmitters
Öffnet einen internen Link im aktuellen Fenster213_028_04 - Monoamines and Metabolites

Pharmaceutical and Biotech

Öffnet einen internen Link im aktuellen Fenster211_004_04 - Glutathione and Other Disulfides
Öffnet einen internen Link im aktuellen Fenster211_005_01 -  Aminothiols and disulfides
Öffnet einen internen Link im aktuellen Fenster217_010_11 - Neomycin and Framycetin Sulfate in bulk drugs
Öffnet einen internen Link im aktuellen Fenster217_013_10 - Gentamicin in Sulphate in Pharmaceutals
Öffnet einen internen Link im aktuellen Fenster217_014_07 - Tobramycin in Pharmaceuticals
Öffnet einen internen Link im aktuellen Fenster217_015_09 - Amikacin and Kanamycin in bulk drugs
Öffnet einen internen Link im aktuellen Fenster217_017_09 - Azithromycin, Erythromycin and other Macrolide Antibiotics
Öffnet einen internen Link im aktuellen Fenster217_018_08 - Spectinomycin in Pharmaceuticals
Öffnet einen internen Link im aktuellen Fenster217_019_06 - Spectinomycin and Lincomycin
Öffnet einen internen Link im aktuellen Fenster217_023_05 - FDG Fluorodeoxyglucose
Öffnet einen internen Link im aktuellen Fenster217_025_03 - Compilation of Pharmaceutical Application
Öffnet einen internen Link im aktuellen Fenster217_026_03 - Risperidone
Öffnet einen internen Link im aktuellen Fenster217_027_03 - Clozapine
Öffnet einen internen Link im aktuellen Fenster217_028_03 - Olanzapine
Öffnet einen internen Link im aktuellen Fenster217_030_03 - Gentamicin acording EP and USP
Öffnet einen internen Link im aktuellen Fenster217_031_02 - Netilmicin Sulfate according EP
Öffnet einen internen Link im aktuellen Fenster217_032_02 - Tobramycin according EP
Öffnet einen internen Link im aktuellen Fenster217_033_02 - Heparin according USP
Öffnet einen internen Link im aktuellen Fenster217_035_02 - Articaine Epinephrine according to USP
Öffnet einen internen Link im aktuellen Fenster217_036_01 - Streptomycin USP method
Öffnet einen internen Link im aktuellen Fenster217_037_01 - Betadex Sulfobutyl Ether Sodium

Legal

Managing Director:
Joachim Paschlau

HRB 135721 München
WEEE-Reg.Nr. DE 66898529

ERC GmbH

Gesellschaft für den Vertrieb wissenschaftlicher Geräte
Otto-Hahn-Strasse 28-30
85521 Riemerling
GERMANY
Tel: +49 89 66055696
Fax: +49 89 60824826
partner@erc-hplc.de